Short answer: most air source heat pumps in England no longer need planning permission. The rules changed on 29 May 2025 - the 1 metre boundary rule was scrapped, unit sizes more than doubled, and detached homes can now have two pumps. But seven conditions still decide it, and failing any one of them puts you back in the application queue.
If you looked into a heat pump two or three years ago and gave up, it is worth looking again.
For years the single biggest obstacle was a rule requiring the outdoor unit to sit at least one metre from your boundary. On a terraced house with a narrow side return, that ruled out almost every sensible position. Octopus Energy reported in 2024 that more than a third of customers who ordered a heat pump never went ahead, and planning was a large part of why.
That rule is gone. The Town and Country Planning (General Permitted Development) (England) (Amendment) Order 2025 came into force on 29 May 2025 and rewrote Class G of Part 14 - the part of the law that governs heat pumps. A second change landed on 28 May 2026, and most homeowners have not heard about that one at all.
Here are the seven rules that now decide whether you need permission, and where people still get caught out.
This is the change that matters most, and it is the one that still has not filtered through to the market.
Under the old rules, the outdoor compressor had to be at least one metre from the edge of your property. It was a blunt instrument. It made no distinction between a quiet unit tucked behind a garden wall and a loud one facing a neighbour's bedroom, and it disqualified thousands of perfectly sensible installations on space grounds alone.
Since 29 May 2025 there is no minimum boundary distance in England. The unit can sit directly against a fence or a party wall, provided it passes the noise test covered in rule 4.
In practice, this reopens heat pumps for the housing stock that needed them most: Victorian terraces, back-to-backs, semis with narrow side passages, and anything in inner London where a metre of clearance was never realistic.
One caveat that catches people out. Removing the boundary rule did not remove the flat roof rule. If you site the unit on a flat roof - a garage, a rear extension, a dormer - every part of it must still be at least one metre from the external edge of that roof. The metre came off your boundary, not off your roof.
The old volume cap was 0.6 cubic metres. It was set in 2011 and had not moved since, and by the 2020s it was quietly excluding the units that larger and older homes actually needed.
The cap on a house is now 1.5 cubic metres, measured on the outdoor compressor unit including its housing. That is not a marginal increase - it is more than double, and it covers essentially every domestic unit on the UK market.
For a block of flats the cap stays at 0.6 cubic metres. This is the detail most guides get wrong: they report the increase and quietly imply it applies everywhere. It does not.
|
Rule |
Before 29 May 2025 |
Now |
|---|---|---|
|
Distance from boundary |
Minimum 1 metre |
No minimum — scrapped |
|
Unit volume (house) |
0.6 cubic metres |
1.5 cubic metres |
|
Unit volume (block of flats) |
0.6 cubic metres |
0.6 cubic metres (unchanged) |
|
Number of units (detached) |
One |
Two |
|
Number of units (semi, terrace, flats) |
One |
One (unchanged) |
|
Air-to-air units with cooling |
Outside permitted development |
Inside, if not solely for cooling |
Detached houses can now install two air source heat pumps under permitted development. This matters for larger properties, cascade systems, and homes zoning heating across a big footprint.
Semi-detached houses, terraces and blocks of flats are limited to one. A second unit at any of those means a planning application, regardless of how small or quiet it is.
There is also a rule almost nobody mentions: you cannot use these rights if there is already a wind turbine on the building or anywhere in its curtilage. It is rare, but it is absolute, and it catches the occasional rural self-builder who installed a turbine years ago and never connected the two things. Detached houses can now install two air source heat pumps under permitted development. This matters for larger properties, cascade systems, and homes zoning heating across a big footprint.
Semi-detached houses, terraces and blocks of flats are limited to one. A second unit at any of those means a planning application, regardless of how small or quiet it is.
There is also a rule almost nobody mentions: you cannot use these rights if there is already a wind turbine on the building or anywhere in its curtilage. It is rare, but it is absolute, and it catches the occasional rural self-builder who installed a turbine years ago and never connected the two things.
With the boundary rule gone, noise is doing all the work it used to share. If your installation fails here, nothing else you got right will save it.
Compliance is assessed under the MCS Planning Standard, MCS 020(a). Your installer runs a sound calculation before installation: they take the manufacturer's sound power level, apply corrections for reflective surfaces within a metre of the unit and for any solid barriers, then calculate the resulting sound pressure at the assessment position - one metre outside the centre of the nearest habitable room window at a neighbouring property.
The number that matters: the calculated level must be 37.0 dB(A) or lower at every assessment position. If it is higher, the installation is not permitted development.
Two things follow from this that are worth knowing before you get quotes.
• A quote that puts the unit tight against a party boundary and says nothing about the sound calculation has skipped a compliance step. Ask to see it.
• The calculation is held on file by the installer. It is not submitted to the council. If a neighbour complains later, that document is your defence.
Barriers help more than people expect. A solid fence or wall between the unit and the neighbouring window can pull the calculated figure down substantially - often enough to turn a failing position into a passing one without moving anything or buying a quieter machine.
This is where a lot of published guidance goes soft, and where softness is actively unhelpful.
Permitted development rights for air source heat pumps do not apply within the curtilage of a listed building. There is no version of this where you install one and hope. The same applies to scheduled monuments.
If your home is listed, you are looking at planning permission and Listed Building Consent, and the second one is the harder conversation. The test is whether the installation harms the special architectural or historic interest of the building - its fabric, its character, its setting.
That is not a refusal. Listed buildings get heat pumps approved regularly. What gets them approved is a rear or concealed position out of public view, a reversible fixing that does not cut into historic fabric, careful routing of pipework, and a heritage statement that argues the case properly rather than treating the application as a formality.
Curtilage is the trap. A listed building's protection can extend to outbuildings, garden walls and gateposts, and to structures that were within the curtilage before July 1948 - even where the main house is not where you are working. Check the National Heritage List before, not after.
Conservation areas are not an automatic bar. This surprises people, because it is the opposite of what most homeowners assume.
You can install under permitted development in a conservation area or World Heritage Site. But the unit must not go on a wall or roof that fronts a highway, and it must not sit nearer to any highway bounding the property than any part of the building does.
In plain terms: the back of the house is fine. The front is not. A corner plot with two highway frontages is where this gets awkward, and it is worth mapping properly before you commit to a position.
Outside conservation areas there is a lighter version of the same restriction. On a wall fronting a highway, the unit cannot go above ground floor level.
Everything above assumes you have permitted development rights in the first place. You might not.
Rights can be stripped in two ways. An Article 4 Direction removes them across a defined area - common in central conservation areas and parts of London. Or a planning condition on a previous permission removes them for your property specifically. Newer estates frequently carry conditions restricting external plant and equipment on elevations, and flat owners often have lease covenants doing the same job privately.
Neither shows up on a heat pump quote. Both are binding.
|
Situation |
What you need |
|---|---|
|
Listed building (or its curtilage) |
Planning permission and Listed Building Consent |
|
Scheduled monument |
Planning permission and scheduled monument consent |
|
Flat or maisonette |
Usually planning permission |
|
Conservation area, unit fronting a highway |
Planning permission |
|
Article 4 Direction in force |
Planning permission |
|
Restrictive planning condition |
Planning permission, or an application to vary the condition |
|
Unit on a pitched roof |
Planning permission |
|
Fails the MCS 020(a) sound calculation |
Planning permission |
There were two dates, not one, and the second passed quietly on 28 May 2026.
Until 28 May 2026, an installation could comply with MCS 020 "or equivalent standards". That flexibility is gone. MCS 020 is now the only permitted certification scheme for permitted development in England. Alternative acoustic methods that were previously acceptable no longer satisfy Class G.
If your installer cannot produce a completed MCS 020(a) sound calculation, you cannot rely on permitted development. It is that simple, and it is now the most common way an otherwise compliant installation falls over.
Guidance that says "UK rules" is guidance you should not trust. Planning is devolved, and the three regimes have drifted apart significantly since 2025.
|
|
England |
Wales |
Scotland |
|---|---|---|---|
|
Boundary distance |
None |
None (from 1 June 2026) |
1 metre still applies |
|
Max volume (house) |
1.5m³ |
1.5m³ |
0.6m³ |
|
Units on detached |
Two |
Two |
One |
|
Current rules in force since |
29 May 2025 |
1 June 2026 |
Pre-2025 rules (unchanged) |
Wales caught up on 1 June 2026, removing its 3 metre boundary rule, raising the house cap to 1.5 cubic metres and the flats cap to 1.3, and allowing two units on detached homes. Before that date, the 3 metre rule made permitted development effectively impossible for most Welsh terraces.
Scotland has not followed. The pre-2025 approach still applies, with draft amendments expected in the Scottish Parliament during summer 2026.
A Lawful Development Certificate is not compulsory. Permitted development is automatic - if you meet every condition, the work is lawful and the council cannot stop it.
What an LDC gives you is proof. It is a formal determination from the council that your installation is lawful, and it is worth having in three situations: where the position is marginal, where you have a neighbour likely to complain, and where you expect to sell or remortgage. Conveyancing solicitors ask about external plant, and "my installer said it was fine" is not an answer that survives due diligence.
The certificate is cheaper and faster than a full application, and it removes the risk of an enforcement conversation years later when you have no leverage and no paperwork.
If the installation needed permission and did not get it, it is unauthorised development. The council can serve an enforcement notice requiring its removal, and there is no four-year immunity to fall back on - that rule was scrapped in April 2024, and the period for most breaches is now ten years.
In practice the trigger is almost always a neighbour complaint about noise. That is when the MCS 020(a) calculation stops being paperwork and starts being the thing standing between you and a removal notice.
If you are already in this position, a retrospective application or an appeal is usually the route out. It is a worse position than applying up front, but it is not the end of the road.
Set against that: a Lawful Development Certificate is cheaper, and a design change that moves the unit two metres is usually free. Most of the time the cheapest application is the one you engineer your way out of needing.
Usually not. Most installations on standard houses in England are permitted development, provided the unit is under 1.5 cubic metres, passes the MCS 020(a) sound calculation at 37.0 dB(A) or lower, and the property is not listed or subject to an Article 4 Direction.
No. It was removed in England on 29 May 2025. You can site a unit directly against a boundary provided the sound calculation passes. The separate 1 metre rule for flat roof edges does still apply.
There is no minimum distance in England. The limit is acoustic, not geometric - if the calculated level at your neighbour's nearest habitable room window is 37.0 dB(A) or lower, the position is compliant.
Only on a detached house. Semi-detached houses, terraces and blocks of flats are limited to one unit under permitted development.
Often not. Permitted development applies in conservation areas, but the unit cannot be on a wall or roof fronting a highway, or nearer to a bounding highway than the building itself. A rear position usually works. Check for an Article 4 Direction as well.
Not under permitted development — those rights do not apply within the curtilage of a listed building. You need planning permission and Listed Building Consent. Approvals are common where the unit is concealed, reversible and supported by a proper heritage statement.
37.0 dB(A) or lower at every assessment position, calculated under MCS 020(a). Guidance quoting 42 dB(A) is referring to the superseded version of the standard.
The rules are more generous than they were, but they are also less forgiving of guesswork. The cases that go wrong are almost never the obvious ones — they are the marginal boundary position, the conservation area corner plot, the planning condition nobody read, the sound calculation that was never run.